Part Number Hot Search : 
MAX7042 APT60 V625TE01 2SB817 MC145 USD750 BSS81 W27C020M
Product Description
Full Text Search
 

To Download AME40-MAZ Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Series AME40-MAZ
40 Watt | AC-DC Converter
FEATURES: * * * * 4000VAC I/O isolation Medical Switching power modules for PCB mounting Operating temperature: -40 to +85C Universal Input: 90-260VAC, 47-440Hz, or 120-370VDC * * * * Energy star compliant RoHS compliant Low Ripple and Noise CE, cULus approvals
Models Single output
Model
AME40-3.3SMAZ AME40-5SMAZ AME40-12SMAZ AME40-15SMAZ AME40-24SMAZ
CB
Input Voltage (VAC/Hz)
90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440
Input Voltage (VDC)
120-370 120-370 120-370 120-370 120-370
Output Voltage (V)
3.3 5 12 15 24
Output Current max (A)
8 8 3.33 2.66 1.66
Efficiency (%)
78 82 84 83 82
Models Dual output
Model Input Voltage (VAC/Hz) Input Voltage (VDC) Output Voltage (V) Output Current max (A) Efficiency (%)
AME40-5DMAZ 90-264/47-440 120-370 5 4 80 AME40-12DMAZ 90-264/47-440 120-370 12 1.66 85 AME40-15DMAZ 90-264/47-440 120-370 15 1.33 82 AME40-24DMAZ 90-260/47-440 120-370 24 0.835 77 NOTE: All specifications are measured at an ambient temperature of 25C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified.
Input Specifications
Parameters
Current Inrush current <2ms Leakage current External fuse Input dissipation Start-up time
Conditions
115 VAC 230 VAC 115 VAC 230 VAC Recommended slow blow type No load; 115VAC No load; 264VAC
Typical
Maximum
1000 530 25 50 150
Units
mA mA A A A A W ms
3.15 <0.5 <0.8 117
Output Specifications
Parameters
Voltage accuracy Line regulation Load regulation Cross regulation Maximum Capacitive load Transient response deviation Ripple & Noise* Hold-up time (min) Minimum Load Current
Conditions
(LL-HL) 0-100% load single 0-100% load dual 25% load - 1st out, 100% load - 2nd out Depending of the model 25% load Step 20MHz bandwidth 115VAC
Typical
2 0.5 1 2 5 470-23 000 2 50 29 0
Maximum
Units
% % % % F % of Vout mV p-p ms % of Max
*Ripple & Noise measured with 0.1F M/C and 1F E/C
www.aimtec.com
F 052e R7
Tel: +1 514 620 2722 1 of 3
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AME40-MAZ
40 Watt | AC-DC Converter Isolation Specifications
Parameters
Tested I/O voltage Input FG Output FG Isolation Resistance
Conditions
3 sec 3 sec 3 sec
Typical
4000 1500 1500 >1000
Maximum
Units
VAC VAC VAC M
General Specifications
Parameters
Switching frequency Over current protection Over voltage protection Short circuit protection Short Circuit restart Operating temperature Maximum case temperature Storage temperature Temperature coefficient Cooling Humidity Case material Weight Dimensions (L X H X W) MTBF
Conditions
Auto recovery
Typical
47 110 Zener diode clamp Hiccup mode, indefinite Auto recovery -40 - +85 -40 to +95 0.02 Free air convection
Maximum
140 110
Units
KHz % %
o o
With derating above 50C
100
C C o C % / oC % RH g
Non condensing Plastic resin + Fiberglass (flammability to UL 94V-0) 300 3.56 x 2.48 x 1.18 inches 90.5 x 63 x 30 mm > 800 000 hrs (MIL-HDBK -217F, t=+25oC)
95
Environment Approval
Test Parameters Wave form Acceleration amplitude Bump duration Converter operation Number of bumps Test mode Displacement Acceleration
Converter operation
Shock
Vibration
Conditions Half sine wave 5gn 30 ms Before and after test, body mounted (on chassis) 18 (3 in each direction for every axis) Sweep sine, 10-100Hz, speed 0.05Hz/s 1 mm 3g, 3 loops 30min one cycle, 3h total, every axis tested Before and after test, body mounted (on chassis)
Safety Specifications
Standards
EMI - Conducted and radiated emission Medical Electrical Equipment Harmonic Current Emissions Voltage fluctuations and flicker Electrostatic Discharge Immunity RF, Electromagnetic Field Immunity Electrical Fast Transient/Burst Immunity Surge Immunity RF, Conducted Disturbance Immunity Power frequency Magnetic Field Immunity Voltage dips, Short Interruptions Immunity cULus, CE, CB EN55011, class B EN 60601-1, CSA-C22.2 No. 601.1-M90 IEC/EN 61000-3-2, (EN60555-2) IEC/EN 61000-3-3, (EN60555-3) IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 IEC 61000-4-6 IEC 61000-4-8 IEC 61000-4-11
Safety
Agency approvals
Pin Out Specifications
www.aimtec.com
F 052e R7
Tel: +1 514 620 2722 2 of 3
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AME40-MAZ
40 Watt | AC-DC Converter
Pin
1 2 3 4 5
Single
AC Input (N) AC Input (L) +V Output -V Output N. C.
Dual
AC Input (N) AC Input (L) +V Output Common -V Output
Dimensions
90.50 (3.56) 2 3 27.94 (1.10) 4 27.94 (1.10) 1
3.56 (0.14) 3.56 (0.14)
63.00 (2.48)
55.88 (2.20)
Top View
5 3.56 (0.14)
3.56 (0.14)
4.60 (0.18)
81.30 (3.20)
4.60 (0.18)
DIV: 10.00 (0.40) 5O 1.30 (O 0.05) Dimensions mm (inch) Case Tolerance 0.50 (0.02) Pin Diameter 1.30 0.05 (0.05 0.002) Pin Pitch Tolerance 0.35 (0.014)
Derating
100 Output Power (%) 80 60 40 20 0 - 40 - 20 0
Free Air Convection
50 C
Safe Operating Area
20
40
60
80
85
100
Ambient Temperature C
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified.5..Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 5. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet.
www.aimtec.com
F 052e R7
Tel: +1 514 620 2722 3 of 3
10.00 (0.40)
1.30 (0.05)
30.00 (0.18)
Side View
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only


▲Up To Search▲   

 
Price & Availability of AME40-MAZ

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X